Lab Test Component | Requirement |
---|---|
Test Name | Prothrombin Time with INR |
Alpha’s Order Test Code | PT |
Specimen Collection Tube | Light Blue Top/Full |
Collection Tube Handling | 1 mL frozen plasma: If the specimen will be delayed longer than 48 hours, centrifuge specimen for 15 minutes at 2500-3500 rpm. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet (buffy) layer and place into a transport tube and freeze at -20° C. Ship on dry ice. |
Minimum Volume | 0.5mL frozen plasma |
Transport Temperture | Frozen |
Stability | Separated platelet-poor plasma: Room temperature: Not acceptable; Refrigerated: Not acceptable; Frozen: 14 days |
Collection Instructions | “One full unopened 3.2% sodium citrate (light blue-top) tube. A completely filled tube is necessary because the correct ratio of blood to citrate is critical (9:1). Mix by gentle inversion 3-4 times. Do not uncap.” |
a. 227 North Greenwood Ave, Fort Smith, AR 72901
a. Getting new CLIA now..Will provide when obtained.
a. 11904 Kanis Rd, H1, Little Rock, AR 72211
b. CLIA: 04D2267958